PI-350/600

Pricing & Availability

The PI and PI-600 Hall effect current sensors accurately measure dc and ac currents and provide electrical isolation between the output of the sensor and the current carrying conductor. These sensors are especially suited for PCB mounting and requirements will small overall size.

 

Measuring Circuit

Units

PI

PI-600

Full scale (FS) dc or ac peak

+A

350

600

Full scale output

mV

175 to 385

150 to 330

Frequency range

Hz

1k

1k

Excitation Circuit

 

 

 

Nominal excitation current (IC)

mA

20

20

Maximum excitation current (IC)

mA

40

40

Input resistance

ohms

30 to 120

30 to 120

Output

 

 

 

Sensitivity

mV/A

0.5 to 1.1

0.25 to 0.55

Linearity

%FS

1.5

2.0

Maximum zero offset

mV

16

16

Maximum hysteresis of offset

mV

2.0

1.4

Minimum load resistance

k ohms

10

10

Influence on Accuracy

 

 

 

Maximum offset drift with temperature

+uV/oC

50

50

Excitation change of +1% max. sensitivity change

+%

1

1

Maximum sensitivity drift with temperature

+%/oC

0.07

0.07

Withstand Capabilities

 

 

 

Dielectric test

kV

6

6

Output short or open

 

NO DAMAGE

NO DAMAGE

 

 

General Information

Units

PI

PI-600

Operating temperature range

oC

-40 to +100

-40 to +100

Storage temperature range

oC

-40 to +110

-40 to +110

Aperture opening

inches (mm)

0.80 (20.3)

0.80 (20.3)

Weight

grams

71

71

 

Output reference: Conventional current flowing in direction of dot or arrow results in a positive difference in VH.

Notes:
All specifications are given with a control current of 40mA.
Due to continuous process improvement, specifications are subject to change without notice.