IHA-25/100/150

Pricing & Availability

The IHA series current sensors are small, rugged, sealed devices.  These sensors accurately measure dc and ac currents and provide electrical isolation between the output of the sensor and the current carrying conductor.

 

Measuring Circuit

Units

IHA-25

IHA-100

IHA-150

Full scale (FS) dc or ac

+A

25

100

150

Frequency range

Hz

50k

50k

50k

Output

 

 

 

 

Full scale output

V

1.0

5.0

5.0

Sensitivity

mV/A

40

50

33.3

Linearity (at +25°C)

% F.S.

1.0

1.0

1.0

Maximum zero offset (at +25°C)

+mV

20

20

20

Influence on Accuracy

 

 

 

 

Maximum offset drift with temperature

+mV/oC

2.0

2.0

2.0

Maximum sensitivity drift with temperature

+%/oC

0.015

0.015

0.015

Withstand Capabilities

 

 

 

 

Dielectric test

kV

6.0

6.0

6.0

Minimum load resistance

k ohms

10.0

10.0

10.0

 

 

 

General Information

Units

IHA-25

IHA-100

IHA-150

Supply voltage

+V

12 to 17

12 to 17

12 to 17

Operating temperature range

oC

0 to +75

0 to +75

0 to +75

Storage temperature range

oC

-25 to +85

-25 to +85

-25 to +85

Aperture opening

inches
(mm)

0.38
(9.7)

0.38
(9.7)

0.84
(21.3)

Weight

grams

26

26

94

 

Due to continuous process improvement, specifications are subject to change without notice.