IF-1000/2000/3000

Pricing & Availability

 

The IF series of current sensors are rugged locomotive, industrial devices. These sensors accurately measure dc and ac currents and provide electrical isolation between the output of the sensor and the current carrying conductor.

IF Series Data Sheet - This file is in PDF format, and is a section of the current sensor catalog.

 

Measuring Circuit

Units

IF-1000

IF-2000

IF-3000

Full scale (FS) dc or ac

+A

1000

2000

3000

Fequency range

Hz

1k

1k

1k

Output

 

 

 

 

Full scale output

V

10.0

10.0

10.0

Sensitivity

mV/A

10

5.0

3.3

Linearity (at +25°C)

% F.S.

0.5

0.5

0.6

Maximum zero offset (at +25°C)

+mV

50

50

50

Influence on Accuracy

 

 

 

 

Maximum offset drift with temperature

+mV/oC

2.0

2.0

2.0

Maximum sensitivity drift with temperature

+%/oC

0.02

0.02

0.02

Withstand Capabilities

 

 

 

 

Dielectric test

kV

2.5

2.5

2.5

Output short or opern

 

No Damage

No Damage

No Damage

 

 

 

General Information

Units

IF-1000

IF-2000

IF-3000

Supply voltage

+V

15

15

15

Operating temperature range

oC

-30 to +75

-30 to +75

-30 to +75

Storage temperature range

oC

-40 to +85

-40 to +85

-40 to +85

Aperture opening

inches
(mm)

1.67
(42.4)

1.67
(42.4)

1.67
(42.4)

Weight

kgrams

1.5

1.5

1.5

 

Due to continuous process improvement, specifications are subject to change without notice.