The small size, low cost, and excellent performance, make the CLS-25 one of the most versatile current sensors in the industry. The CLS-25 is a closed-loop current sensor, with primary current passing through sealed conductors that can be adjusted to measure from 6 amps nominal to 25 amps nominal. This sensor is capable of measuring DC and AC currents and provides electrical isolation between the circuit being measured and the output. This sensor is suitable for industrial, automotive, appliances, and consumer electronics, and is an excellent replacement for a shunt or current transormer. | Measuring Circuit | Units | CLS-25 | | Full scale (FS) dc or ac peak | +A | 6, 8, 12, 25 | | Supply voltage ( + 5% ) | +V | 15 | | Frequency range | kHz | 200 | | Output | | | | Turns ratio | A/A | 4,3,2,1 : 1000 | | Linearity (at +25°C) | % Nominal | 0.2 | | Maximum zero offset (at +25°C) | +mA | 0.15 | | Nominal analog output current | mA | 25 | | Maximum offset drift (0oC to +70oC) | +mA | 0.6 | | Current consumption (plus output current) | mA | 10 | | Measuring resistance range | Ohms | 54 to 360 |
| General Information | Units | CLS-25 | | Operating temperature range | oC | -40 to +85 | | Storage temperature range | oC | -40 to +90 | | Weight | grams | 17 | Due to continuous process improvement, specifications are subject to change without notice. |