The CLN series with their small size, low cost, and excellent performance is one of the most versatile current sensors in the industry. The CLN series are closed-loop current sensors, with the primary current passing through a center aperature. This sensor is capable of measuring DC and AC currents and provides electrical isolation between the circuit being measured and the output. | Measuring Circuit | Units | CLN-50 | CLN-100 | | Full scale (FS) dc or ac | +A | 90 | 150 | | Supply voltage | +V | 12 to 15 | 12 to 15 | | Frequency range | kHz | 150 | 150 | | Output | | | | | Turns ratio | A/A | 1:1000 | 1:1000 | | Overall accuracy (at +25°C) | % Nominal | 0.5 | 0.5 | | Linearity (at +25°C) | % Nominal | 0.1 | 0.1 | | Maximum zero offset (at +25°C) | +mA | 0.2 | 0.2 | | Nominal analog output current | mA | 50 | 100 | | Maximum offset drift (-25oC to +85oC) | +mA | 0.8 | 0.8 | | Current consumption (plus output current) | mA | 10 | 14 | | Measuring resistance range | Ohms | 50 - 100 | 10 - 85 | | General Information | Units | CLN-50 | CLN-100 | | Operating temperature range | oC | -40 to +85 | -40 to +85 | | Storage temperature range | oC | -40 to +90 | -40 to +90 | | Aperture opening | inches | 0.53 x 0.39 | 0.53 x 0.39 | | Weight | grams | 18 | 21 | Due to continuous process improvement, specifications are subject to change without notice. |