CLN-300SP1/500SP1

Pricing & Availability

The CLN series with their small size, low cost, and excellent performance, is one of the most versatile current sensors in the industry. The CLN series are closed-loop current sensors, with the primary current passing through built in bus bar. This sensor is capable of measuring DC and AC currents and provides electrical isolation between the circuit being measured and the output.

 

 

Measuring Circuit

Units

CLN-300SP1

CLN-500SP1

Full scale (FS) dc or ac

+A

600

1200

Supply voltage

+V

12 to 18

15 to 24

Frequency range

kHz

150

100

Output

 -

Turns ratio

A/A

1:2000

1:5000

Overall accuracy (at +25°C)

% Nominal

0.5

0.5

Linearity (at +25°C)

% Nominal

0.1

0.1

Maximum zero offset (at +25°C)

+mA

0.3

0.2

Nominal analog output current

mA

150

100

Maximum offset drift (0oC to +70oC)

+mA

0.5

0.3

Current consumption (plus output current)

mA

14

22

Measuring resistance range

Ohms

5 - 70

5 - 130

 

 

General Information

Units

CLN-300SP1

CLN-500SP1

Operating temperature range

oC

-40 to +85

-40 to +85

Storage temperature range

oC

-40 to +90

-40 to +90

Weight

grams

730

885

 

Due to continuous process improvement, specifications are subject to change without notice.