300 WATTS | | CE-300 SERIES | | Features - Universal 85-264 VAC Input
- High Efficiency
- Compact 4.9" X 8.5" X 1.95" Size
- Class B Emissions Per EN 55022
- 2 Year Warranty
- EN 60950 ITE Certification
- Harmonic Current per EN 61000-3-2
- EMC to EN 61000-6-2
- One to Five Regulated Outputs

| | Total Output Power | 300 W | | Output Voltage Centering | Output 1-5: +/-0.5% (All outputs at 50% load) | | Source Regulation | Outputs 1-5: 0.5% | | Load Regulation | | Output 1-5:1% (10-100% Load Change) | | Cross Regulation | Output 2-5: 0.5% (Output 1 load varied 50-100%)) | | Output Voltage Adjust Range | Output 1-3: 95% to 105% | | Output Noise | Outputs 1-4: 1% | | | | | Turn On Overshoot | None | | Transient Response | Outputs 1-5 | | Volt. Deviation | 5% | | Recovery Time | 2 mS | | Load Change | 50% To 100% | | Output Overvoltage Protection (Optional) | Output 1: 120% to 150%% | | Output Overpower Protection | 340 W Min. | | Outputs cycle on/off, auto recovery | | Output Overcurrent Protection | 110% Min., Outputs 2,3,4 & 5 | | Hold Up Time | 20 mS Min, 300 W Output 120 V Inputt | | Start Up Time | 3 Second |
| | Source Voltage | 85-264 Voltage AC | | Frequency Range | 47-63 Hz | | Source Current | | | True RMS | 5.8A At 85V Inputut | | Peak Inrush | 20A | | Peak Repetive | 8.2A at 85V Input | | Harmonic Distortion | 0.05 | | Efficiency | .68 -.80 (Varies by model) | | Power Factor | 0.90(300W, 230V) |
| | | ENVIRONMENTALAL SPECIFICATIONS | |
| Ambient Operating Temperature Range | 0oC to +50oC Derating: See Power Rating Chart | | Ambient Storage Temperature Range | -40oC to +85oC | | Temperature Coefficient | Outputs 1-5: 0.02%/oC |
|
| | | General | | Protection Class: | I | | Overvoltage Category: | II | | Pollution Degree: | 2 |  | Underwriters Laboratories File E137708 | UL 60950, Third Edition | |  | UL Recognition Mark for Canada File E137708 | CAN/CSA-C22.2 No. 60950:00 | |  | TUV | EN 60950:2000 | |  | | Low Voltage Directive | |
| | Dielectric Strength | | Reinforced Insulation | 4242 VDC, Primary to Secondary, 1 Sec. | Basic Insulation | 2121 VDC, Primary to Ground, 1 Sec. | Operational Insulation | 500 VDC, Secondary to Ground, 1 Sec. | | Power Fail Signal | Logic low with input power failure 2 mS minimum prior to output 1 dropping 1% | | Remote On/Off (Optional) | Contact closure shuts off all outputs | | Remote Sense (outputs 1 & 2) | 230mV compensation of output cable losses | | Weight | 3.3 Lbs. |
| | Model | Output 1 | Output 2 | Output 3 | Output 4 | Output 5 | | CE-300-5001 | +5V/40A | +24V/4A | +12V/6A | -5V/1A | -12V/2A | | CE-300-5002 | +5V/40A | +12V/8A | -12V/6A | -5V/1A | +24V/2A | | CE-300-5003 | +5V/40A | +12V/8A | +24V/3A | -15V/1A | +15V/2A | | CE-300-5004 | +5V/40A | +24V/4A | 24V/3A | -12V/1A | +12V/2A | | CE-300-5005 | +24V/8A | +12V/8A | +5V/6A | -15V/1A | +15V/2A | | CE-300-5006 | +24V/8A | 24V/4A | +5V/6A | -15V/1A | +15V/2A | | CE-300-5012 | +5V/40A | +28V/3A | +12V/6A | -5V/2A | -12V/2A | | CE-300-5013 | +5V/40A | 3.3V/6A | +24V/4A | -5V/1A | +12V/2A | | CE-300-4001 | +5V/40A | +12V/8A | -5V/5A | | -12V/2A | | CE-300-4002 | +5V/40A | +24V/4A | +24V/4A | | -12V/2A | | CE-300-4003 | +5V/40A | +24V/4A | +24V/4A | | -15V/2A | | CE-300-4004 | +24V/8A | +12V/8A | +5V/5A | | -12V/2A | | CE-300-4005 | +5V/40A | -5.2V/12A | +5V/4A | | -12V/2A | | CE-300-4006 | +24V/8A | +12V/8A | | -12V/1.5A | 5V/2A | | CE-300-4009 | +24V/8A | +12V/8A | +5V/5A | | -12V/2A | | CE-300-4011 | +5V/40A | +3.3V/12A | | +12V/2A | -12V/2A | | CE-300-3001 | +5V/40A | +12V/8A | -12V/6A | | | | CE-300-3002 | +5V/40A | +12V/8V | +24V/3A | | | | CE-300-3003 | +5V/40A | +15V/6A | -15V/4A | | | | CE-300-3004 | +12V/16A | -12V/8A | +5V/6A | | | | CE-300-3006 | +5V/40A | +3.3V/12A | | +12V/2A | | | CE-300-2001 | +5V/40A | +24V/4A | | | | | CE-300-2002 | +12V/16A | -12V/8A | | | | | CE-300-2003 | +15V/13A | -15V/6A | | | | | CE-300-2004 | +24V/8A | -24V/A4 | | | | | CE-300-1001 | 5V/60A | | | | | | CE-300-1002 | 12V/25A | | | | | | CE-300-1003 | 15V/20A | | | | | | CE-300-1004 | 24V/12A | | | | |
|
| | Notes | | | Consult factory for alternate output configuration. Consult factory for positive, negative or floating output 2. Refer to Application Information for complete output power ratings. All specifications are maximum at 25oC unless otherwise stated and are subjected to change without notice. Specify optional power fail, overvoltage protection or remote on/off when ordering. CE-300-4006: TUV only |
| | CE-300 SERIES MECHANICAL SPECIFICATIONS | |
| 
| | | Maximum Output Power vs. Ambient Temperature |
| 
| | | TB1 | AC Input | Terminal Block with 6-32 screws on 0.325 centers mates with #6.0.25 inch wide spade terminals. (10 in-lb max) | | TB2 | DC Output | Terminal Block with 6-32 screws on 0.325 centers mates with #6.0.25 inch wide spade terminals. (10 in-lb max) | | +/- | DC Output | 10-32 threaded studs mate with tongue terminals. | | P1 | Option/Sense | .100 breakaway header mates with Molex 22-01-2127 or equivalent crimp terminal housing with Molex 6459 or equivalent crimp terminal. |
|
| - Semiconductor case temperature must not exceed 110 oC.
- Each output can deliver its rated current but total output power must not exceed
65 watts. - Semiconductor case temperature must not exceed 110 oC
- Sufficient area must be provided around convection cooled power supplies to allow natural movement of air develop.
- This product is intended for use as a professionally installed component within information technology and medical equipment.
- A minimum load of 10% is required on output one to insure proper regulation of remaining outputs.
- Peak to peak output ripple and noise is measured directly at the output
terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth. - This product was type tested and safety certificated using the the dielectric strength test voltages listed in Table V of UL 60950. In consideration of clause 5.2.2, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages be used when performing a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
- This power supply has been safety approved and final tested using a DC
dielectric strength test. Please consult factory before performing AC dielectric strength test. - Maximum screw penetration into mounting holes is .250 inches
|
|
|
|
|
|